Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.
hilmor Trades Month Save 10%

Carrier® WeatherMaster® - 6 Ton High Efficiency Gas Heat/Electric Cooling Packaged Rooftop Unit (208/230-3-60)

Item: 48HCDA07A2A5-0A0A0
MFR: 48HCDA07A2A5-0A0A0

Availability

Sign in to see real-time inventory at the stores closest to you.
What’s the price?
Sign in for pricing.

Frequently Bought Together

Best Sellers

Refrigerant & Oils

About This Product

Product Info

Description

48HCDA07A2A5-0A0A0
48 = Gas Heat Pkg. Rooftop / Product Type
HC = High Efficiency / Product Series
D = Low Gas Heat / Heat Options
A = Single Stage Cooling / Refrigerant & System Options
07 = 6 ton / Nominal Cooling Capacity (Tons)
A = None / Sensor Options
2 = Medium Static Option - Belt Drive / Indoor Fan Options
A = Al/Cu - Al/Cu / Coil Options (RTPF) (Outdoor - Indoor)
5 = 208/230-3-60 / Voltage
- = Factory Design Revision
0 = Electromechanical Controls can be used with W7212 EconoMi$er (Non-Fault Detection and Diagnostic) / Base Unit Controls
A = None / Intake / Exhaust Options
0 = None / Service Options
A = None / Electrical Options
0 = Standard / Packaging

FEATURES AND BENEFITS
  • Single-stage cooling capacity control on 04 to 07 models, 2-stage cooling capacity control on 07 to 14 models
  • SEER up to 15.6, EER up to 13.0
  • IEER's up to 14.0 with single speed indoor fan motor, and up to 16.0 with SAV™ (Staged Air Volume) 2-speed/VFD indoor fan motor system
  • Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Gas efficiencies up to 82%
  • Induced draft combustion design
  • Redundant gas valve, with up to 2 stages of heating
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
  • TXV refrigerant metering system on each circuit
  • Fully insulated cabinet
  • Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving indoor fan motor delay
  • Dedicated 3-5 ton “Low NOx” models available that meet California Air Quality Management NOx requirement of 40 nangram/joule or less. Low NOx models include stainless steel heat exchangers
  • Cooling operating range up to 125°F (52°C), and down to 35°F (2°C), 0°F (-18°C) on 11 size standard
  • Access panels with easy grip handles
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Two-inch disposable return air filters
  • Tool-less filter access door
  • Belt drive evaporator-fan motor and pulley combinations available on all three phase models
  • Electric Drive X13 (5 speed/torque) motor on 04 to 06 models
  • Central terminal board (CTB) facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Field Convertible airflow (3-12.5 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 12.5 ton models require a simple supply air duct cover to field convert from factory vertical to horizontal.
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point gas and electric connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots
  • Scroll compressors with internal line-break overload protection
  • 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low-pressure switch and high-pressure switch protection
  • Exclusive IGC anti-cycle protection for gas heat operation
  • Solid-state electronic direct spark ignition system
  • Flame roll-out safety protector
  • Liquid line filter drier on each circuit
  • Factory-installed Humidi-MiZer® Adaptive Dehumidification System on all sizes, includes Motormaster® I controller.
  • Standard Warranty: 10 yr. aluminized heat exchanger, 15 yr. stainless steel heat exchanger, 5 yr. compressor, 1 yr. parts.
  • Optional SAV system utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor fan motor speed between cooling stages. Available on 2-stage cooling models 07-14 with electro-mechanical, ComfortLink or RTU Open controls.
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov

Specifications

Weight765 Pounds (lbs)
Length59.5 Inches (In)
Width88.125 Inches (In)
Height41.25 Inches (In)
Country of OriginMEX
AFUE81%
Air FlowConvertible
Blower Motor RPM733-949
Blower Motor TypeECM
BrandCarrier
BTU Input50000
BTU Output41000
CFM1500
ColorGray
CompressorScroll
Condenser Motor HP1/3 HP
Cooling Capacity35600
Cooling Rated Capacity Btu/h72000
Cycle/Hertz60
Drain Connection Size3/4"
Drive TypeBelt
EER12
Energy Star RatedYes
ETL ListedNo
Filter Size(2) 16" x 25" x 2"
Heat Exchanger TypeAluminized or Stainless Steel
IEER13
Ignition TypeDirect Spark
ISO CodeMX
Nominal EER12
Number of Fan Blades1
PhaseThree
Product Family48HC
Prop 65Yes
RefrigerantR-410a
SEER15
Sound Level (dBA)76
StageTwo
TierWeatherMaster
Tonnage3
UL ListedYes
UL RecognizedYes
Voltage575 VAC
Warranty OfferedYes
Watts190

Documents