Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.
ecobee 4 Pro

Carrier® Performance™ - 3 Ton 16 SEER 90000 Btuh Residential Packaged Gas Heat & Electric Cooling Unit 2-Stage

Item: 48VG-B360903-TP
MFR: 48VG-B360903-TP

Availability

Sign in to see real-time inventory at the stores closest to you.
What’s the price?
Sign in for pricing.

Frequently Bought Together

Best Sellers

Pads Mounts & Blocks

Disconnects & Whips

Thermostats

Refrigerant & Oils

Other

About This Product

Product Info

Description

Options
GP - Base unit with tin plated indoor coil hairpins and Stainless Steel HX (Single Phase Only)
GS Stainless Steel HX
TF Filter Rack
TP Base unit with tin plated indoor coil hairpins (Single Phase Only)
Only used if ordering an option

Single-Packaged Products with Energy-Saving Features and Puron® refrigerant.
  • 15.0 to 16.0 SEER
  • 12.0 - 12.5 EER
  • 81% AFUE (Single phase models)
  • Meets Energy Star requirements
  • Direct Spark Ignition
  • Factory-Installed TXV
  • Multi-speed ECM Blower Motor-Standard
  • Sound Levels as low as 72dBA
  • Two Stage Cooling
  • Two Stage Heating (208/230 VAC models)
  • Dehumidification Feature
FEATURES / BENEFITS
One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance.
Puron Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems proving highly reliable, environmentally sound performance.
Easy Installation
Factory-assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/cooling size combinations with voltage options to meet
residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications.
Innovative Unit Base Design
On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging.
Convertible duct configuration
Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode.
Efficient operation
High-efficiency design
offers SEER (Seasonal Energy Efficiency Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%.
Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units.
Low NOx units designed for California installations. These models meet the California maximum oxides of nitrogen (NOx) emissions requirement of 40 nanograms/joule or less as shipped from the factory and MUST be installed in California Air Quality Management Districts and wherever a Low NOx rule exists.
Durable, dependable components
Compressors have two stages of cooling and are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection.
Monoport inshot burners produce precise air-to-gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment.
Turbo-tubular™ heat exchangers are constructed of aluminized steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air.
In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer.
Stainless steel heat exchanger available as factory installed option.
Multi-speed ECM Blower Motor is standard on all models.
High Efficiency 2-Speed Inducer Motor on single phase models.
Direct-drive PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40°F (4.4°C) outdoor temperature. Motormasterr II low ambient kit is available as a field-installed accessory.
Thermostatic Expansion Valve - A hard shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency.
Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier.
High and Low Pressure Switches provide added reliability for the compressor.
Indoor and Outdoor coils are computer-designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit.
Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 72dBA.
Dehumidification Feature
This unit has independent fan speeds for low stage cooling and high stage cooling. In addition, 208/230 VAC models have the field-selectable capability to run an enhanced dehumidification (’DHUM’) speed on high stage cooling (as low as 320CFM per ton). Coupled with the improved dehumidification associated with low stage cooling, the DHUM speed allows for a complete dehumidification solution independent of cooling stage. 208/230 VAC models also have independent fan speeds for low stage gas heating and high stage gas heating. The dehumidification control must open the control circuit on humidity rise above the dehumidification set point.
Heating
  • Reliable direct spark ignition system
  • Inducer motors with ball bearings
  • Low stage heating delivers 65% of high-stage capacity (208/230 VAC models)
Easy to service cabinets provide easy 3-panel accessibility to serviceable components during maintenance and installation. The basepan with integrated drain pan provides easy ground level installation with mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4-in. (19.05 mm) wide perimeter flange makes frame mounting on a rooftop easy.
Standard horizontal metal duct covers with insulation come with the unit and cover the horizontal duct openings. These can be left in place if the units are converted to downflow.
Integrated Gas Control (IGC) board provides safe and efficient control of heating and simplifies trouble-shooting through its built-in diagnostic function.
Cabinets are constructed of heavyduty, phosphated, zinc-coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator/heat exchanger compartment are insulated with foil-faced insulation, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers 62.2.) The sloped drain pan minimizes standing water in the drain. An external drain is provided.
Louvered grille provides hail and vandalism protection for the coil.

Specifications

Weight447 Pounds (lbs)
Length44.125 Inches (In)
Width48.8125 Inches (In)
Height44.75 Inches (In)
Country of OriginMEX
AFUE81%
Blower Motor HP3/4 HP
Blower Motor RPM1000
Blower Motor SpeedsNot Provided
Blower Motor TypeECM
Blower Wheel11" x 10"
BrandCarrier
BTU Input90000
BTU Output0
CFM Cooling1200
Circuit Breaker - Max Amps0
Circuit Breaker - Min Amps0
ColorNot Provided
CompressorScroll
Condenser Motor HP1/5 HP
Condenser Motor RPM810
Condenser Motor SpeedsNot Provided
Condenser Motor TypePSC
Cooling Capacity35400
Cooling Rated Capacity Btu/h36000
Cycle/Hertz60 Hz
Drain Connection Size0.25
Drive TypeNot Provided
EER12.5-13.5
Filter Size24" x 30" x 1"
Fuel TypeNatural Gas (Factory Installed) or LP Convertible
Full Load Amps1.2
Gas ConnectionNot Provided
Gas Heating Capacity74000
Heat Exchanger TypeTubular
Heating Capacity0
High Pressure LimitsYes
IEER0
Ignition TypeDirect Spark
Locked Rotor Amps83
Maximum Fuse Size40
Metering DeviceTXV
Minimum Circuit Amps26.3
Nominal EER12
Number of Fan Blades1
PhaseSingle
Product Family48VG-A
Prop 65No
Rated Current Amps0
Rated Load Amps15.3
RefrigerantR-410a
SEER16
Sound Level (dBA)73
StageTwo
Thermal EfficiencyNot Provided
TierPerformance
Tonnage3
Voltage208-230 VAC
Warranty OfferedYes

Documents

Equipment Part List

Loading...
‡Ductless Stock Up and Save offer valid thru May 31, 2019 at participating CE locations. Account must be active and in good standing condition to qualify for terms. Excludes special pricing and all accessories. Special quotes, OEM parts & job pricing excluded. Not valid on previous purchases. Offer cannot be combined with other offers or programs. Management reserves the right to modify or end this promotion at any time without notice. Orders must be placed and taken delivery by May 31, 2019.