Your browser is not supported. For the best experience, you should upgrade to a modern browser with improved speed and security.
Easystock

Carrier® Performance™ Ductless 5 Zone System 4 Ton Heat Pump with (2) 9,000, (2) 12,000 and (1) 18,000 Btu High Walls

Item: CARMAQ4853HW
What’s the price?
Sign in for pricing.

Frequently Bought Together

Best Sellers

Disconnects & Whips

Ductless Controls

About This Product

Product Info

Description

Performance series ductless systems offer that perfect balance between budget limits you may have today and your desire for energy savings and comfort options.

New for 2016, the 38MAR heat pump achieves full heating capacity even as temperatures outside dip to 5° F (in select sizes). This model lives up to its Performance name with features like variable speed operation for extra efficiency and reduced sound.

STANDARD FEATURES
  • 100% Heating Capacity at 5° F (-15° C)*
  • Up to 25.0 SEER cooling efficiency
  • Up to 12.0 HSPF heating efficiency
  • Variable Speed (Inverter) Compressor
  • Base pan heater
  • Factory installed Crankcase Heater
  • Compact footprint
  • Improved outdoor serviceability
  • Auto louver mode
  • Turbo mode
  • 4 indoor unit fan speeds
  • Auto-restart function
  • Condenser high temp protection
  • Refrigerant leakage detection
  • Indoor sound: as low as 27 decibels1
  • 46°F heating mode (heating setback)
  • Low voltage controls
  • Sleep mode
  • Follow me
  • Line lengths 82-164' depending on unit capacity
  • 10-year parts limited and 10-year compressor limited warranties to the original purchasing owner upon timely registration2

CONTROL STANDARD FEATURES
Wireless remote control standard
Optional wired remote control

1 Quietest size within each model group during low fan-speed operation

2 If properly registered within ninety (90) days after original installation, parts are warranted to the original purchaser for a period of 10 years. Otherwise, parts warranty is 5 years. For other applications a 7-year parts and 7-year compressor limited warranties apply. See warranty certificate for details.

* Sizes 9-24 (208/230V)
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov

Specifications

BrandCarrier
Cycle/Hertz60 Hz
Mounting TypeHigh Wall
Number of HVAC Zones5
PhaseSingle
Prop 65Yes
TierPerformance
Tonnage4
Voltage208-230 VAC

Documents

Bundle Components

Carrier® Performance™ Ductless 12000 Btu Heat Pump High Wall

Item: 40MAQB12B--3

Description

FEATURES / BENEFITS

A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT.
The 40MAQ series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This selection of fan coils permits creative solutions to design problems such as:
  • Add-ons to current space (an office or family room addition)
  • Special space requirements
  • When changes in the load cannot be handled by the existing system
  • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork
  • Historical renovations or any application where preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.
LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since the outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 40MAQ ductless systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these high wall systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless system indoor and outdoor units are designed to provide years of trouble-free operation.
The high wall indoor units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-current protection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply-air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted while air moves through the ducts.
EASY−TO−USE CONTROLS
The high wall units have microprocessor−based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless split systems to your application is easily accomplished.
Adding a condensate pump accessory to the high wall fan coil provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.

Specifications

Weight19.2 Pounds (lbs)
Length7.8 Inches (In)
Width32.9 Inches (In)
Height11 Inches (In)
Country of OriginCHN
Blower Motor HP1/20 HP
Blower Motor RPM1350
Blower Motor Speeds4
BrandCarrier
CertificationsAHRI Certified
CFM380
Circuit Breaker - Max Amps15
ColorWhite
Condenser Motor HP1/5 HP
Cooling Capacity12000
Cooling Rated Capacity Btu/h12000
Cycle/Hertz60 Hz
Drain Connection Size5/8"
EER13
Energy Star RatedYes
ETL ListedYes
Heating Capacity5000-13500
HSPF10
Liquid Line FittingFlare
Liquid Line Size (OD)1/4"
Maximum Fuse Size15
Maximum Piping Length82'
Minimum Circuit Amps15
PhaseSingle
Product Family40MAQ
Prop 65Yes
Rated Current Amps0.07
Rated Load Amps5.7
RefrigerantR-410a
Rows2
SEER21
Sound Level (dBA)27
Suction Line FittingFlare
Suction Line Size (OD)1/2"
TierPerformance
Tonnage1
UL ListedNo
Voltage208-230 VAC
Warranty OfferedYes
Watts20

Carrier® Performance™ Ductless 9000 Btu Heat Pump High Wall

Item: 40MAQB09B--3

Description

FEATURES / BENEFITS

A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT.
The 40MAQ series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This selection of fan coils permits creative solutions to design problems such as:
  • Add-ons to current space (an office or family room addition)
  • Special space requirements
  • When changes in the load cannot be handled by the existing system
  • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork
  • Historical renovations or any application where preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.
LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since the outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 40MAQ ductless systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these high wall systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless system indoor and outdoor units are designed to provide years of trouble-free operation.
The high wall indoor units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-current protection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply-air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted while air moves through the ducts.
EASY−TO−USE CONTROLS
The high wall units have microprocessor−based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless split systems to your application is easily accomplished.
Adding a condensate pump accessory to the high wall fan coil provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.

Specifications

Weight19.2 Pounds (lbs)
Length7.8 Inches (In)
Width32.9 Inches (In)
Height11 Inches (In)
Country of OriginCHN
Blower Motor HP1/20 HP
Blower Motor RPM1350
Blower Motor Speeds4
BrandCarrier
CertificationsAHRI Certified
CFM380
Circuit Breaker - Max Amps15
ColorWhite
Condenser Motor HP1/10 HP
Cooling Capacity9000
Cooling Rated Capacity Btu/h9000
Cycle/Hertz60 Hz
Drain Connection Size5/8"
EER14.5
Energy Star RatedYes
ETL ListedYes
Heating Capacity4500-11500
HSPF10
Liquid Line FittingFlare
Liquid Line Size (OD)1/4"
Maximum Fuse Size15
Maximum Piping Length82'
Minimum Circuit Amps15
PhaseSingle
Product Family40MAQ
Prop 65Yes
Rated Current Amps0.07
Rated Load Amps5.3
RefrigerantR-410a
Rows2
SEER23
Sound Level (dBA)27
Suction Line FittingFlare
Suction Line Size (OD)3/8"
TierPerformance
Tonnage0.75
UL ListedNo
Voltage208-230 VAC
Warranty OfferedYes
Watts20

Carrier® Performance™ Ductless 18000 Btu Heat Pump High Wall

Item: 40MAQB18B--3

Description

FEATURES / BENEFITS

A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT.
The 40MAQ series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This selection of fan coils permits creative solutions to design problems such as:
  • Add-ons to current space (an office or family room addition)
  • Special space requirements
  • When changes in the load cannot be handled by the existing system
  • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork
  • Historical renovations or any application where preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels.
LOW SOUND LEVELS
When noise is a concern, the ductless split systems are the answer. The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through ductwork.
SECURE OPERATION
If security is an issue, outdoor and indoor units are connected only by refrigerant piping and wiring to prevent intruders from crawling through ductwork. In addition, since the outdoor units can be installed close to an outside wall, coils are protected from vandals and severe weather.
FAST INSTALLATION
This compact ductless system is simple to install. A mounting bracket is standard with the indoor units and only wire and piping need to be run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in the home or workplace. This makes the 40MAQ ductless systems the equipment of choice, especially in retrofit situations.
SIMPLE SERVICING AND MAINTENANCE
Removing the top panel on outdoor units provides immediate access to the control compartment, providing a service technician access to check unit operation. In addition, the draw-thru design of the outdoor section means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and detergent.
On all indoor units, service and maintenance expense is reduced due to easy-to-use cleanable filters. In addition, these high wall systems have extensive self-diagnostics to assist in troubleshooting.
BUILT-IN RELIABILITY
Ductless system indoor and outdoor units are designed to provide years of trouble-free operation.
The high wall indoor units include protection against freeze-up and high evaporator temperatures on heat pumps.
The condensing units on heat pumps are protected by a three minute time delay before the compressor starts the over-current protection and the high temperature protection.
INDIVIDUAL ROOM COMFORT
Maximum comfort is provided because each space can be controlled individually based on usage pattern. The air sweep feature provided permits optimal room air mixing to eliminate hot and cold spots for occupant comfort. In addition, year-round comfort can be provided with heat pumps.
ECONOMICAL OPERATION
The ductless split system design allows individual room heating or cooling when required. There is no need to run large supply-air fans or chilled water pumps to handle a few spaces with unique load patterns. In addition, because air is moved only in the space required, no energy is wasted while air moves through the ducts.
EASY−TO−USE CONTROLS
The high wall units have microprocessor−based controls to provide the ultimate in comfort and efficiency. The user friendly wireless remote control provides the interface between the user and the unit.
ACCESSORIES
Customizing these ductless split systems to your application is easily accomplished.
Adding a condensate pump accessory to the high wall fan coil provides installation flexibility.
OPTIONAL WIRED CONTROLLER
AGENCY LISTINGS
All systems are listed with AHRI (Air Conditioning, Heating & Refrigeration Institute), and ETL.

Specifications

Weight26.5 Pounds (lbs)
Length8.6 Inches (In)
Width39 Inches (In)
Height12.4 Inches (In)
Country of OriginCHN
Blower Motor HP1/15 HP
Blower Motor RPM1350
Blower Motor Speeds4
BrandCarrier
CertificationsAHRI Certified
CFM680
Circuit Breaker - Max Amps20
ColorWhite
Condenser Motor HP1/8 HP
Cooling Capacity17500
Cooling Rated Capacity Btu/h18000
Cycle/Hertz60 Hz
Drain Connection Size5/8"
EER12.5
Energy Star RatedYes
ETL ListedYes
Heating Capacity5500-19000
HSPF9.6
Liquid Line FittingFlare
Liquid Line Size (OD)1/4"
Maximum Fuse Size20
Maximum Piping Length98'
Minimum Circuit Amps15
PhaseSingle
Product Family40MAQ
Prop 65Yes
Rated Current Amps0.17
Rated Load Amps7.3
RefrigerantR-410a
Rows2
SEER19
Sound Level (dBA)33
Suction Line FittingFlare
Suction Line Size (OD)1/2"
TierPerformance
Tonnage1.5
UL ListedNo
Voltage208-230 VAC
Warranty OfferedYes
Watts58

Equipment Part List

Loading...
Motor Season